Our Compliance Partners

Hot & Cold Water Tank Repair and Lining Services

AmTech’s HydraStone USA division is proud to be the exclusive U.S. licensee of the HydraStone Alkrete® system for relining tanks.

HydraStone USA & DuraChem water tank lining and repair systems

Related Services

Fire Suppression Water Tank Lining

Potable Water Tank Lining

Wastewater Tank Lining

Using HydraStone Cementitious Lining for Industrial Hot Water Tank Repairs

There comes a point when service is needed in the productive lifespan of each hot water tank. When inspection reveals that the present cementitious or thin mil epoxy lining is failing, AmTech can complete a hot water tank repair and relining. Failure to reline the tank will result in further erosion, which will eventually permeate the outer steel wall, resulting in tank failure and facility downtime.

AmTech’s HydraStone USA division provides peace of mind for hospitality, manufacturing, educational and institutional facilities that cannot afford the disruption of a hot water tank failure. Our inspection, repair, and Alkrete® water tank relining services, such as fiberglass tank lining, tank coating, and abrasive sandblasting, have enabled thousands of industrial, municipal, and commercial hot water tank owners to extend the productive life of their Domestic Hot Water (DHW) tanks. We have delivered similar savings, longevity and security for facilities that needed potable water tank lining, wastewater tank lining and fire suppression water tank lining. By choosing our periodic tank maintenance and relining services, your facility will gain decades of serviceable use and save tens of thousands of dollars in capital expenditures.

Affordable Hot Water Tank Repair Services
Replacing a Corroded Tube Bundle Like This Can Add Years of Service Life
Replacing the Corroded Tube Bundle During a Water Storage Tank Repair
Opening Commercial Hot Water Tank for Inspection & Relining

Using HydraStone Alkrete Water Tank Lining System for Commercial Hot Water Tank Repairs

Using the HydraStone Alkrete®  water tank lining system designed for potable hot water tanks, our field crews reline domestic and commercial storage tanks, both pressurized and atmospheric, in all 50 US states and Canada. 

Alkrete® is completely resistant to virtually any condition inside a hot or cold water tank, including softened water and extremely high temperatures. With an outstanding 40 year history, Alkrete is known as the number one lining material for this application. Alkrete, handling temperatures up to 900° Fahrenheit, is a proprietary product of HydraStone.

The Alkrete® lining system is the top choice of many original equipment DHW tank manufacturers as an OEM factory lining. HydraStone is the largest field installer in North America of cementitious tank linings and engineered sacrificial anodes.

Before the industrial hot water tank lining begins

Hot Water Tank Before Lining

A corroded and pitted domestic hot water storage tank. If the corrosive action had continued, the tank would soon have required costly replacement.

After the Professional Hot Water Tank Relining Has Been Completed

Hot Water Tank After Lining

The finished product: an NSF-approved HydraStone cement lining was applied at a minimum 5/8″ thickness, and further corrosion has been stopped. The hot water tank was relined on-site, and put back into service within 30 hours.

Tube Bundle Replacement Options

Maintaining DHW Hot water tanks for peak performance, HydraStone’s field teams also replace faulty tube bundles and sacrificial anodes when needed. With long-term submersion, tube bundles eventually deteriorate, allowing water to leak between the hot water system and the boiler water system. Tube bundles and sacrificial anodes can be replaced at the time of lining to minimize downtime and provide greater protection from future water tank leak repairs.

DuraChem water tank lining systems & solutions
Installing a Tube Bundle To Prevent Water Tank Leaks
Installation of Tube Bundle

Using HydraStone Cement Lining for Cold Water Tank Repairs

Large cold water storage tanks, normally used for buildings in need of large amounts of water when supply cannot keep up with demand, need a periodic inspection to preserve their structural integrity. When the existing internal coatings show signs of failure, these tanks can be efficiently re-lined and quickly returned to service using our HydraStone Alkrete® cement lining. Cold-water storage tanks from 1,000 gallon to two million gallon capacity or greater are no problem.

HydraStoneUSA Hot Water Tank Relining & Repair
An Old & Corroded Water Storage Tank in Need of Repair

Old & Corroded Water Storage Tank

Old & Corroded Water Storage Tank

Pneumatic Water Tank Repair

Fire suppression water storage tanks are subject to internal oxidation and migrational pitting when their internal coatings fail. Typically atmospheric, and large in size, these tanks provide large amounts of cold water to protect buildings from damage by fire. Due to the importance of this tank and the amount of water damage a leak could cause to a building, it is very important to prevent severe corrosion from taking place. Using AmTech Pro-Line® Epoxy Linings, our HydraStone Alkrete® cement linings, or our DuraChem® 500 series Polylinings, our applicator teams can provide a quality lining system with a life span of 15 years and beyond.

A Pneumatic Water Tank Before Relining

Pneumatic Tank Before Lining

Water storage tanks, which contain both liquid and air under pressure, can be considered hydro-pneumatic tanks. These tanks are originally lined with various protective coatings to prevent corrosion. AmTech will recommend a specific coating to reline your tank along with a preventative maintenance program, which will easily double the life of the vessel.

The Look After a Hydro-Pneumatic Water Storage Tank Repair

Pneumatic Tank After Lining

Condensate return tanks are commonly in service under atmospheric pressure. Storing steam condensate, these tanks are high in temperature, creating an environment difficult to protect. Alkrete®, handling temperatures up to 900° Fahrenheit, outperforms other linings, making it an excellent choice for corrosion protection in high-temperature environments.

For a no obligation project evaluation and lining sample, please call our Customer Service Engineering Department at 888-839-0373 or send us a message. Ask about our best warranty program in the business.

Armor Shield® Tank Linings • Poly Lining Systems • DuraChem Poly Lining Systems • Amtech Pro-line® Products • Alkrete Cement Lining Systems • Xypex Concrete Waterproofing
Loading...