Surface Preparation
Engineer-led crews assess corrosion, existing coatings, substrate integrity, humidity, and dew point before blasting or profiling tank surfaces to SSPC, NACE, and ASTM requirements.
Protect bolted storage tanks from corrosion, leaks, chemical attack, and premature failure with engineered coating and sealing solutions from AmTech Tank Lining & Repair. Our field crews evaluate each tank, prepare surfaces to specification, seal vulnerable joints and penetrations, and apply proven lining systems designed to extend service life while reducing costly downtime.

Engineered coating, sealing, surface preparation, and lining services for steel and concrete storage tank assets.
Engineer-led crews assess corrosion, existing coatings, substrate integrity, humidity, and dew point before blasting or profiling tank surfaces to SSPC, NACE, and ASTM requirements.
PLS 755 Tank Tape bridges gaps, pipe penetrations, nozzle openings, weld seams, and uneven joints to create a smooth bonding surface before lining application.
DuraChem 500 series polylinings create seamless, chemical-resistant barriers for tanks storing corrosive, acidic, alkaline, and temperature-sensitive industrial liquids.
AST floor pan coating includes inspection, steel repair, abrasive blasting, and instant-cure DuraChem lining to protect vulnerable tank bottoms from corrosion.
AmTech applies zero-VOC DuraChem linings that resist hydrogen sulfide, fluctuating pH, biological activity, and abrasive solids in wastewater tank environments.
Port Seal and Xypex crystalline waterproofing seal cracks, pores, joints, and penetrations in concrete tanks, basins, and below-grade containment structures.

AmTech begins with an engineer-led evaluation of tank material, stored product, corrosion depth, lining condition, joint details, penetrations, and operating demands. The findings guide material selection, surface preparation standards, and the coating or sealing system best suited to the tank.
AmTech combines proven materials, engineering oversight, and nationwide field capability.
Decades of tank lining experience help facilities extend service life and avoid replacement costs.
Field engineering support guides inspections, specifications, material selection, and application protocols.
Experienced AmTech crews deploy across all 50 states, Canada, and the Caribbean.
DuraChem, HydraStone, Armor Shield, and AT BiFlex systems address demanding storage conditions.
Engineering guidance for complex tank lining projects.

CS Project Engineer / NLPA Special Inspector
Greg Comeau serves as AmTech's CS Project Engineer and NLPA Special Inspector, bringing specialized expertise in commercial tank assessment, regulatory compliance, and complex lining system design. As a licensed NLPA Special Inspector, Greg conducts detailed tank integrity evaluations, ultrasonic permeation testing, and structural assessments that form the foundation of every AmTech project. His engineering oversight ensures that surface preparation, material selection, and application protocols meet or exceed API, NFPA, ANSI, and NSF standards. Greg manages projects across multiple industries—from Fortune 500 chemical facilities to municipal water systems—coordinating field crews, specifying proprietary lining systems, and providing technical guidance throughout the installation process. With direct oversight of both routine maintenance projects and emergency response situations, he ensures that every tank restoration delivers maximum service life extension while minimizing facility downtime. Greg is the primary contact for project inquiries, technical consultations, and employment applications.
Coating and sealing a bolted storage tank typically includes inspection, cleaning, surface preparation, joint and penetration sealing, coating or lining application, and final verification. AmTech evaluates the tank’s substrate, stored product, corrosion condition, and operating environment before selecting systems such as DuraChem, HydraStone, Armor Shield, AT BiFlex, PLS 755 Tank Tape, or crystalline waterproofing products.
Talk with AmTech about your tank condition and lining options.
AmTech field crews travel to industrial, municipal, and commercial tank sites across broad regions.
All 50 States
Service Area
US, Canada, Caribbean
Coverage
Emergency Services
Response
Confirm availability for inspections, repairs, coatings, and emergency work.
Supports recognized industry performance and safety standards.
Protective systems aligned with UL listing requirements.
OSHA 10 and OSHA 30 training credentials.
Share your tank type, stored product, location, and current concern. AmTech will help determine the right inspection, repair, coating, or sealing approach for your facility.
For immediate assistance, feel free to give us a direct call at 888-839-0373. You can also send us a quick email at gregc@amtechtanklining.com.
For immediate assistance, feel free to give us a direct call at 888-839-0373. You can also send us a quick email at gregc@amtechtanklining.com.