Ultrasonic Leak Detection
Advanced ultrasonic permeation testing identifies minute leaks, wall thinning, and pinholes invisible to visual inspection. Non-destructive testing ensures regulatory compliance and prevents catastrophic tank failures.
Protecting Framingham properties from costly water damage starts with early detection. AmTech's advanced ultrasonic permeation detection and emergency repair crews identify hidden leaks in tanks, piping, and storage systems before they escalate into major failures, keeping your facility compliant and operational year-round.

From pinpoint leak detection to emergency structural repairs, we deliver comprehensive solutions for all water storage system failures.
Advanced ultrasonic permeation testing identifies minute leaks, wall thinning, and pinholes invisible to visual inspection. Non-destructive testing ensures regulatory compliance and prevents catastrophic tank failures.
Rapid-response crews mobilize to address active leaks, sudden corrosion breakthroughs, and structural failures. We arrive with instant-cure repair materials to restore tank integrity and minimize facility downtime.
Complete inspection, structural steel repair, and re-lining of domestic hot water tanks, HVAC buffer tanks, and thermal storage systems using high-temperature resistant HydraStone Alkrete lining technology.
Custom laminate repairs for cracked, delaminated, or chemically degraded fiberglass tanks. We rebuild damaged areas with compatible glass, Kevlar, or carbon veils and replace leaking nozzles with proper structural bonding.
Crystalline waterproofing systems penetrate concrete to permanently seal micro-cracks and prevent water infiltration at extreme hydrostatic pressures. Self-healing technology reactivates when new moisture appears.
API 653-compliant steel repairs for corroded tank bottoms, perforated walls, and failed nozzle attachments. Welded patches restore structural integrity before protective lining systems are applied.

Engineer-led crews arrive on-site with ultrasonic testing equipment to scan tank walls, bottoms, and critical zones. We map wall thickness variations, identify permeations, and document all structural anomalies. For Framingham facilities facing New England freeze-thaw cycles, we pay special attention to weld seams and nozzle penetrations where seasonal expansion stresses concentrate.
Over 55 years of field-proven expertise protecting water storage systems across New England.
Rapid deployment across Massachusetts with crews ready to address active leaks, structural failures, and regulatory compliance emergencies.
Ultrasonic permeation testing identifies leaks at the earliest stage—long before visual signs appear—preventing catastrophic tank failures and water damage.
Exclusive U.S. licensee of HydraStone Alkrete and developer of DuraChem instant-cure linings. Our engineered systems outperform traditional coatings in demanding New England conditions.
Every project is staffed by experienced, OSHA-certified technicians backed by field engineering support. We perform all work in-house—never subcontractors—ensuring consistent quality and accountability.
Experienced engineers and certified technicians serving Massachusetts facilities.

CS Project Engineer / NLPA Special Inspector
Greg Comeau serves as AmTech's CS Project Engineer and NLPA Special Inspector, bringing specialized expertise in commercial tank assessment, regulatory compliance, and complex lining system design. As a licensed NLPA Special Inspector, Greg conducts detailed tank integrity evaluations, ultrasonic permeation testing, and structural assessments that form the foundation of every AmTech project. His engineering oversight ensures that surface preparation, material selection, and application protocols meet or exceed API, NFPA, ANSI, and NSF standards. Greg manages projects across multiple industries—from Fortune 500 chemical facilities to municipal water systems—coordinating field crews, specifying proprietary lining systems, and providing technical guidance throughout the installation process. With direct oversight of both routine maintenance projects and emergency response situations, he ensures that every tank restoration delivers maximum service life extension while minimizing facility downtime. Greg is the primary contact for project inquiries, technical consultations, and employment applications.
Hidden leaks often present as unexplained water loss, increased utility bills, moisture stains on surrounding surfaces, or musty odors near the tank. Older tanks may show external rust or corrosion patterns even when the interior leak is small. AmTech's ultrasonic permeation testing detects leaks at the micron level—identifying wall thinning, pinholes, and compromised welds before they become visible or cause structural failure. For facilities in Framingham, we recommend annual inspections for tanks over 15 years old or any system showing signs of corrosion.
Talk to our Massachusetts-based engineers for a free site assessment and repair estimate.
Approved for potable water contact.
Tank inspection and repair standards.
All field personnel safety trained.
Contact AmTech today for a no-obligation site inspection and detailed repair proposal. Emergency services available 24/7.
For immediate assistance, feel free to give us a direct call at 888-839-0373. You can also send us a quick email at info@amtechtanklining.com.